100% Individual Coil Testing
No random batch testing. Every single coil is physically & electrically verified before dispatch.
10,000 MΩ Resistance
We hit a massive 10,000 MΩ insulation resistance, far exceeding the 3,000 MΩ industry standard.
100% Water Tested
Any manufacturing defects are destroyed on our factory floor. You receive 100% defect-free product.
Garware Polyester
Exclusively insulated with Garware Polyester film, the absolute gold standard for thermal endurance.
IS 8783 Technical Standards
| Test Description | Standard | VEI Pass Criteria |
|---|---|---|
| In-Line Spark Test | IS 8783 (Part 3) | 10,000V (10 kV) (Zero Pinholes) |
| Water Immersion HV Test | IS 8783 (Part 4/Sec 3) | 3.0 kV AC for 1 min |
| Volume Resistivity (27°C) | IS 8783 (Part 2) | ≥ 1 × 10¹&sup6; Ω·cm (> 10,000 MΩ) |
| Heat Shock Test | IS 10810 (Part 14) | 150°C for 1h (No cracks) |
| Conductor Elongation | IS 8783 (Part 1) | Min 24% to 40% (Pure CC) |